DOLD

Extention modules feed


DOLD extension, delay and coupling modules

Extension modules

Extension modules can be used to multiply the output contacts of the basis modules. Also contact reinforcement by splitting into multiple control circuits is possible.

Delay modules

The emergency-stop of a dangerous movement can be accelerated by a controlled stop operation according to the stop category 1 by allowing motor brake functions or controlled drive speed reduction to run during the cutout delay.

Coupling modules

Coupling modules with positively driven contacts are used to switch safety-related functions as links between logic circuitry and load.  The positively driven NC contacts can be used to monitor the closing contacts.

Advantages

 

Extension modules

  • Cost-saving contact multiplication, universal connectivity to all basis modules
  • Monitor output contacts via a feedback loop through the relevant basis module
  • Connect multiple extension modules to a single basis module by cascading

Delay modules

  • Controlled stop operation of drives minimizes the risk of injuries
  • No adverse effects on productivity as immediate restarting is possible
  • High long-term stability by digital timer

Coupling modules

  • Very safe switching behaviour by positively driven contacts
  • Allow a regulation-compliant implementation of safety-related circuits
  • Prevent retriggering in the case of an error

Technology

 

Extension modules

Compact module with positively-driven safety relays which is triggered by the associated function module (basis module) and monitored via a feedback loop. An extension module can only reach the basis module’s safety category acc. to EN 954-1 as a maximum.

Delay modules

Delay-release time-delay relay with or without auxiliary voltage and adjustable or fixed time setting. High long-term stability thanks to digital timer. Two time circuits working independent of each other to implement a cutoff redundancy. Positively driven release contacts.

Coupling modules

Coupling modules feature safety relays with positively driven contacts according to EN 50205. Positive-action is present if the contacts are mechanically linked to each other so that NC and NO contacts can never be closed at the same time. For this it must be ensured that a contact gap of at least 0.5 mm is present over the whole service life, even in fault condition.

Applications

Extension modules

Multiplication of release circuits of a basis module to cut off any number of control circuits in a safety-related manner.

Delay modules

Quick stopping of a dangerous movement of drives with masses.
A typical example are tools rotating with high speed, which still coast after cutoff for a longer time.

Coupling module

Used, for example, for self-monitoring safety circuits, for the adjustment of control and power levels and for switching safety-related functions.


Extension modules SAFEMASTER ®
All products mentioned comply with the safety category 4 acc. to EN 954.
Function Output contacts,
max.
Breaking current Schaltstrom
Ith [A] max.
Detachable
terminals
Width
[mm]
Type


DCAC



Extension modules 5NO +   5 A + 22.5 LG 5929
Extension modules 5NO +   5 A + 22.5 BG 5929
Extension modules 7NO, 1NC + + 10 A + 100 BN 3081
NO = normally open contact, NC = normally closed contact


Interface modules, positive-action SAFEMASTER ®
1-channel, optionally also suited for low loads
Function Output contacts,
max.
nominal voltage Breaking current
Ith [A] max.
Detachable
terminals
Width
[mm]
Type


DCAC



Interface module 3NO, 2NC   + 5 A   18 HC 3096
Interface module,
optionally with pin base
3NO, 2NC   + 8 A   38 HL 3094
Interface module,
optionally with pin base
4NO, 1NC   + 5 A   38 HL 3096
Interface module 2NO + + 8 A   17.5 IK 3079
Interface module 4NO, 3NC + + 8 A   70 IP 3078, SP 3078
Interface module 5NO, 1NC   + 5 A + 22.5 LG 3096, MK 3096N
NO = normally open contact, NC = normally closed contact


Delay modules SAFEMASTER®
Function Safety
category
according
to EN 954
1-channel/
2-channel
Output
contacts,
max.
nominal voltage Auxiliary
voltage
required
Breaking
current
Ith [A] max.
Time delay
max.
Detachable
terminals
Width
[mm]
Type




DCAC





Release delayed, fixed
or adjustable time range
2 1 1NO, 1NC + +   8 A 3 s   35 IL 7824
Release delayed, fixed
or adjustable time range
2 1 1NO, 1NC + +   8 A 10 s + 52.5 IN 7824
Release delayed, fixed 3 1 5NO, 1NC       5 A 3 s + 22.5 BG 7926
Release delayed, fixed
or adjustable time range
2 1; 2 1NO, 1NC + +   8 A 30 s   45 BA 7924
Release delayed, fixed
or adjustable time range
3 1; 2 3NO, 1NC + + optional 5 A 10 s + 45 BH 7925
Release delayed,
adjustable time range
3 1; 2 1NO, 1NC + + + 7 A 10 s   22.5 BG 7925
NO = normally open contact, NC = normally closed contact
For multiple monitored timers combined with further safey functions see SAFEMASTER®M











Sort by:
Name Code Image Description Data
BG7926 D BG 7926 BG7926
Delay module BG 7926, release delayed download
BH7925 D BH 7925 BH7925
Delay module BG 7925, BH 7925, release delay download
BN3081 D BN 3081 BN3081
Extension module BN 3081 download
HC3906 D HC 3906 HC3906
Interface module HC 3096, HL 3096 download
HL3094 D HL 3094 HL3094
Interface module HL 3094, HO 3094, HO 3095 download
IK3079 D IK 3079 IK3079
Interface module IK 3079 download
IL7824 D IL 7824 IL7824
Delay module BA 7924, IL 7824, IN 7824, release delay. download
IP3078 D IP 3078 IP3078
Interface module IP 3078, SP 3078 download
LG3096 D LG 3096 LG3096
Interface module LG 3096, MK 3096N download
LG5929 D LG 5929 LG5929
Extension module LG 5929 download


  • «« Start
  • « Prev
  • 1
  • Next »
  • End »»


Display #  
Results 1 - 10 of 10