Radel

  • Increase font size
  • Default font size
  • Decrease font size
Home Line Card Products Relays Safety Relays Emergency stop modules
Print

DOLD

Emergency stop modules feed


Emergency stop modules / monitors

In 1988, DOLD developed their first emergency stop module BN 5983 for man-machine protection. Conventional contactor controls with their expensive interconnection wiring could be replaced with this product and a lot of space could be saved in the control cabinet. With current emergency stop modules featuring a width of only 17.5 mm and a depth of only 70 mm, DOLD has again set new standards for safety relay modules.

In large installations with multiple emergency-stop buttons, it is useful to quickly know which emergency-stop button has been operated to minimise downtimes. For this application DOLD offer specific emergency stop button monitors with indication and bus outputs.

Advantages

Emergency stop modules

  • Safety category up to EN 954, SC4
  • Safe thanks to potential-free contacts
  • Miniaturization space saving designs
  • Gold-plated contacts, for low loads
  • Easy wiring saves cost
  • Tailored to your applications
  • Quick module replacement via detachable terminals
  • Preconfigured type-tested modules save time and cost

Emergency stop monitors

  • Quick identification of the depressed emergency-stop button via clear LED indication
  • Reduced downtime, due to fast location of the depressed emergency-stop button
  • A choice of signalling to primary controls and displays via bus interface or BCD coded outputs

Technology

Emergency stop modules 

The function of an emergency-stop module is to quickly and reliably stop a dangerous movement in when a potential hazard is identified. This is why appropriate circuits are incorporated to prevent failure of devices downstream from an emergency-stop control device. Dependant upon a risk assessment and the resultant safety category, these circuits are designed with the following features:

  • Redundancy
  • Cyclically monitored
  • Fail-safe operation

Further features

  • Potential-free outputs with positively driven contacts
  • Compliance with EN 954

Emergency stop monitors

The green status LED’s are illuminated for non-operated emergency-stop buttons. When an emergency-stop button is depressed, the associated LED will go out.

The emergency-stop buttons are series connected; this is why only one LED will go out if multiple emergency-stop buttons are operated. In this case, only the depressed emergency-stop button which is closest to the front position in the emergency-stop chain is signalled.  When this emergency-stop button is unlocked, the next depressed emergency-stop button is indicated.

Applications

 

Emergency stop modules

 

Stop dangerous movements or cut off energy in case of danger to protect man, machine and product.

They are used in machinery and plants which may cause danger to man or machine, e.g. in the packaging industry, production plants, food industry, material handling, plastic processing, steel and aluminium industry, woodworking industry.

 

Emergency stop monitors

 

Monitor emergency-stop buttons in large plants to quickly locate the depressed emergency-stop button, e.g. in industrial applications, materials handling, sewage treatment and woodworking plants.


 

Emergency stop modules SAFEMASTER ®
All products mentioned comply with the safety category 4 acc. to EN 954.

Also suited as
safety
Function
gate monitor
Safety category
acconting to
EN 954-1 1)
Performance Level
to EN 13849-1 1)
SIL Claimed Level
EN 62061 1)
1-channel/
2-channel
Output contacts, max. Breaking current Ith [A] max. cross fault
detection
nominal voltage Detachable terminals width [mm] Type









DCAC


Emergency stop module with var. Terminals   4 2) 2) 1 4NO 5 A   + + + 22.5 LG 5924
Emergency stop module with var. Terminals + 4 e 3 1; 2 4NO 5 A + + + + 22.5 LG 5925
Emergency stop module with var. Terminals + 4 e 3 1; 2 8NO, 1NC 5 A + + + + 45 LH 5925
Emergency stop module   4 e 3 1 4NO 7 A   + + + 22.5; 70 BG 5924, IP 5924
Emergency stop module, most compact design   4 e 3 1 1NO 5 A   +     17.5 RK 5942
Emergency stop module + 4 2) 2) 1; 2 2NO 10 A + + +   45 BD 5987
Emergency stop module + 4 2) 2) 1; 2 3NO 7 A + + + + 22.5 BG 5925
Emergency stop module + 4 2) 2) 1; 2 3NO,1NC 5 A + + + + 45 BH 5919
Emergency stop module + 4 2) 2) 1; 2 3NO, 1NC 10 A   + +   100 BN 5983
Emergency stop module + 4 2) 2) 1; 2 3NO, 1NC 10 A + + +   45 BD 5935
Emergency stop module + 4 2) 2) 1; 2 4NO, 1NC 5 A + + + + 90 BL 5926
Emergency stop module with integrated
short-circuit protection
+ 4 2) 2) 1; 2 4NO, 1NC 5 A + + + + 90 BL 5927
Emergency stop module + 4 2) 2) 1; 2 7NO, 1NC 10 A + + + + 90 BL 5931
Emergency stop module with delay up to 300s +   e 3 1;2 2NO,
1NO contact delayed
8 A + +   + 22.5 LG 5928 New !
Emergency stop module with delay up to 300s + 4 e 3) 1; 2 3NO,
3NO contact delayed
5 A + +   + 45 BH 5928
Emergency stop module with delay up to 300s + 4 e 3) 1; 2 3NO,
3NO contact delayed
5 A +   + + 67.5 BI 5928
Emergency stop module
with power failure detection
  4 2) 2) 1; 2 3NO 5 A +   + + 90 BH 5903
Emergency stop module
with power failure detection
  4 2) 2) 1; 2 3NO 5 A +   + + 90 BL 5903
Emergency stop module + 4 e 3 1; 2 3NO, 1NC 10 A +   +   100 BN 5930.48/203,
BN 5930.48/204
NO = normally open contact, NC = normally closed contact , NO contact delayed
For multiple monitored emergency-stop buttons in combination with further safety functions see SAFEMASTER®C and SAFEMASTER®M
BD 5934,BN 5930.48,BO 5988.61,BO 5988.47

 



Emergency stop monitors SAFEMASTER®
Function Inputs, max. 1-channel
2-
channel
DC 24 V Breaking current Ith [A], max. Width [mm] Type







Emergency stop monitor 8 1; 2 + 10 A 45 BH 5922
Emergency stop monitor 16 1; 2 + 10 A 90 BL 5922
The emergency stop monitors can be combined with our emergency stop modules.






Sort by:
Name Code Image Description Data
BD5935 D BD 5935 BD5935
Emergency Stop Module BD 5935, Output: optionally 1 NO / 1 NC or 3 NO / 1 NC contacts, Gold plated contacts to switch low loads (signal to PLC), 1- or 2-channel connection, Line fault detection on ON pushbutton, Operating state display, LED display for ch download
BD5987 D BD 5987 BD5987
Emergency Stop Module BD 5987, Output: 2 NO contacts for AC 250 V, Gold-plated contacts to switch small loads (input for PLC), 1-channel or 2-channel connection, Line fault detection at On pushbutton # Operating state display download
BG 5924 D BG 5924 BG 5924
Emergency Stop Module BG 5924, Single channel operation, Output: max. 4 NO contacts, AC 230 V model with galvanic separation, For thermal currents to 7 A, LED indicator for channel 1 / 2 and state of operation download
BG 5925 D BG 5925 BG 5925
Emergency Stop Module BG 5925, Output: max. 3 NO contacts, see contacts, Single and 2-channel operation, Line fault detection on On-button, Manual restart or automatic restart when connecting the supply voltage, switch S2 download
BH5903 D BH 5903 BH5903
Emergency Stop Module BH 5903, E-stop with latching function, Automatic start when voltage returns after phase failure when no E-Stop was operated before phase failure.,Reset after E-stop with push button, Output max. 3 NO contacts, see contacts, download
BH5922 D BH 5922 BH5922
Emergency Stop Module BN 5922,To monitor max. 16 single-channel e-stop buttons,or 8 2-channel e-stop buttons,E-stop button can be connected directly to BH 5922, As option direct connection of 2-channel e-stop buttons to BH 5922 / BL 5922, Simple wiring o download
BH5928 D BH 5928 BH5928
Emergency Stop Module BH 5928, Output: 3 NO or 2 NO, 1 NC instantaneous contacts and 3 NO release delayed contacts, Single and 2-channel operation, Line fault detection on On-button, when On-button is connected to S33-S34, Manual restart with button on download
BL5926 D BL 5926 BL5926
Emergency Stop Module BL 5926, Output: 4 NO, 1 NC contacts for AC 250 V, 1- or 2-channel connection, Automatic restart, Line fault detection on ON push-button with bridge X2/X3 download
BL5927 D BL 5927 BL5927
Emergency Stop Module BL 5927, Output: 4 NO, 1 NC contacts for AC 250 V,1 NO indication contact, Contact Y32, Y35 gold-plated to switch low loads (input of PLC), 1- or 2-channel connection, Automatic restart download
BL5931 D BL 5931 BL5931
Emergency Stop Module BL 5931, Output: max. 7 NO, 1 NC contacts for AC 250 V, 1- or 2-channel connection, Line fault detection at the On pushbutton, Optionally automatic on feature when operating voltage applied or activation via the On pushbutton download
BN5930.48/203 D BN5930.48/203 BN5930.48/203
Emergency Stop Module BN5930.48/203, BN 5930.48/203 with cross fault detection by connecting 2 different phases, max. 400 V,BN 5930.48/204 with cross fault detection by connecting phase and neutral, max. 230 V, download
BN5983 D BN 5983 BN5983
Emergency Stop Module BN 5983, Output: 3 NO, 1 NC contacts for AC 400 V, Optionally gold-plated contacts to switch small loads (input for PLC), 1-channel or 2-channel connection, LED displays for channels 1 and 2 download
BO5988 D BO 5988 BO5988
Emergency Stop Module BO 5988, Output: max. 6 NO, 1 NC contacts or 1 NO contact for AC 250 V, Optionally with release delayed NO contact to 10 min, 1-channel or 2-channel connection, Line fault detection at On pushbutton download
LG5924 D LG5924 LG5924
Emergency Stop Module LG 5924, Single channel operation, Output: max. 4 NO contacts, AC 230 V model with galvanic separation, LED indicator for channel 1 / 2 and state of operation download
LG5925 D LG5925 LG5925
Emergency Stop Module LG 5925, # Output: max. 4 NO contacts, see contacts, Single and 2-channel operation, Line fault detection on On-button, Manual restart or automatic restart when connecting the supply voltage, switch S2, With or without cross fault mo download
LG5925 D LG 5925 LG5925
Emergency Stop Module LG 5925, Output: max. 4 NO contacts, see contacts, Single and 2-channel operation, Line fault detection on On-button, Manual restart or automatic restart when connecting the supply, voltage, switch S2 download
RK 5942 D RK 5942 RK 5942
Emergency Stop Module RK 5942, extremly small, Single channel operation, Output: 1 NO contact and 1 monitoring logic output, LED-indicator for relay 1 / 2 and supply voltage download


  • «« Start
  • « Prev
  • 1
  • Next »
  • End »»


Display #  
Results 1 - 17 of 17

Products